truCCOMS® Cardiac Output Measurement is based on an innovative application of thermodynamic heat transfer principles, capable of detecting rapid changes in Cardiac Output. It is the only CO monitoring system that provides real-time continuous, accurate information. It offers the following advantages:
Real Advantages » True Real-Time monitoring - When every second counts, real-time cardiac output monitoring allows the clinicians to respond to the patient's needs instantly. truCCOMS combines speed with the accuracy necessary for effective monitoring allowing instantaneous clinical intervention. With truCCOMS second-by-second information, you can observe the effects of therapy such as fluid challenges and inotropic support as they happen.
» Use in coronary artery bypass surgery - Gives indications of possible adverse effects resulting from manipulating the heart during surgery. Unlike many other cardiac output monitoring devices truCCOMS can be used in the presence of Intra-Aortic Balloon Pump (IABP) counterpulsation.
» Heparin coated - Less potential from thrombus or bacteria adherence to catheter.
Real Convenience
» No Calibration- Needs no calibration during use and frequent thermodilution procedures are not required, saving valuable time during monitoring.
» Flexibility- Dual Function Cardiac Output Options - users can select to use either continuous CO monitoring or intermittent cardiac output measurements using traditional TD techniques with the truCATH catheter. » Simple to Use- truCATHTM insertion uses familiar techniques, so there is no need for lengthy familiaristation training.
» Patient Friendly- Minimal intervention leading to less stress on patients already compromised.
» User Friendly- Easy to read display with trending information available at the touch of a button through its convenient touch screen controls.
Real Accuracy
» truCCOMS - combines speed with the accuracy necessary for effective monitoring and treatment needs no calibration during use and frequent thermodilution procedures are not required, saving valuable time during monitoring.
» Cardiac Output Measurement Specifications:
Continuous Mode: »Range 1 to 20 litres per minute » Accuracy* 3% or 0.3 litres per minute, whichever is greatest » Response < One Second
Injectate Mode: » Range 1 to 20 litres per minute » Accuracy* 3% or 0.3 litres per minute, whichever is greatest » Response < One Second
Blood Temperature Range: » 25-45oC. Blood temperature fluctuations do not adversely affect the performance of truCCOMS.
Using an innovative application of the Mass-Heat Transfer principle, the Omega truCCOMS® is fundamentally different from all other CO measurement technologies.